Jobs / United States / Nebius B.V.

Nebius B.V.

Structured Cabling Design Engineer

Remote - Europe · Remote · Europe Posted 4 days ago

Apply on employer site ↗ Tailor my CV first Source: Company careers site

Optional: we can tailor a CV and cover letter for this job from your real experience first (the first one is free).

Skills this job asks for

Machine learningNetworkingBudgetingProcurement

Add your CV (free) to see which of these your CV is missing.

Where you can work from

Europe only

Based on the listing's location: Remote - Europe.

The company's headquarters is not the same as where you may work from. Visa sponsorship only matters if you would relocate; see below.

Visa sponsorship, if you would relocate

Sponsorship verdict

No sponsorship evidence yet

No government record and no wording either way. Not a refusal: ask the recruiter.

  • No government sponsor record hereThis employer does not appear with approvals in the government data SponsorApply holds.
  • The posting doesn’t mention sponsorshipSilence isn’t a refusal — ask the recruiter before investing much time.
  • No salary bar for this routeH-1B has no fixed salary bar: the employer must pay at least the prevailing wage for the role and area.
  • Confirmed live todayWhen a source last listed this job as open.
Details and sources
No salary bar for this route
H-1B has no fixed salary bar: the employer must pay at least the prevailing wage for the role and area. Cap-subject employers enter a lottery weighted by wage level. Source: https://www.federalregister.gov/documents/2025/12/29/2025-23853/weighted-selection-process-for-registrants-and-petitioners-seeking-to-file-cap-subject-h-1b, rules effective 2026-02-27.

US H-1B: cap-subject employers enter a lottery weighted by wage level — Level I gets 1 entry, Level IV gets 4 (DHS projected selection odds ≈15% at Level I to ≈61% at Level IV). Universities and non-profit research employers are cap-exempt. The $100,000 fee for new petitions from abroad is currently blocked by a court order (appeal pending).

A verdict summarises public evidence. It is not legal advice and never a guarantee: the employer and the immigration authority decide. Sign in to factor in where you can already work.

Before you apply

Sponsorship unknown

No register record and no sponsorship wording in the posting. Worth asking the employer before investing significant time.

These come from the posting’s own wording. Read the original listing to confirm. See better-fit alternatives →

About the role

About Nebius: Nebius is leading a new era in cloud infrastructure for the global AI economy. We are building a full-stack AI cloud platform that supports developers and enterprises from data and model training through to production deployment, without the cost and complexity of building large in-house AI/ML infrastructure. Built by engineers, for engineers. From large-scale GPU orchestration to inference optimization, we own the hard problems across compute, storage, networking and applied AI. Listed on Nasdaq (NBIS) and headquartered in Amsterdam, we have a global footprint with R&D hubs across Europe, the UK, North America and Israel. Our team of 1,500+ includes hundreds of engineers with deep expertise across hardware, software and AI R&D. The role We are seeking an experienced Structured Cabling Design Engineer to support the design and delivery of structured cabling and physical network infrastructure for hyperscale and enterprise data center environments. This remote position will be responsible for developing scalable, standards-compliant fiber and copper cabling designs from concept through construction and deployment. The engineer will work closely with data center design, network engineering, construction, operations, vendors, and deployment teams to ensure cabling infrastructure meets capacity, reliability, maintainability, and future-growth requirements. Key Responsibilities • Develop end-to-end structured cabling designs for new-build, expansion, retrofit, and capacity-add data center projects. • Design fiber-optic and copper cabling systems supporting data center network, compute, storage, management, security, and building infrastructure. • Develop MDF, IDF, MMR, network room, meet-me-room, and data hall connectivity designs . • Create fiber backbone, horizontal cabling, interconnect, cross-connect, and equipment connectivity architectures. • Develop single-line diagrams, cabling schematics, rack elevations, patching diagrams, pathway layouts, fiber routing plans, and connectivity schedules . • Determine fiber counts, cable types, connector types, patch-panel requirements, termination methods, and pathway capacity. • Design solutions using single-mode and multimode fiber , including high-density fiber connectivity and MPO/MTP-based systems where applicable. • Specify Category 6/6A copper infrastructure and associated patching systems. • Perform cable pathway, tray, conduit, ladder rack, and containment capacity calculations. • Coordinate structured cabling requirements with network architecture, electrical, mechanical, architectural, security, and construction disciplines. • Review construction drawings, BIM/CAD models, specifications, submittals, RFIs, and vendor proposals. • Develop Bills of Materials (BOMs) and support material forecasting and procurement. • Create and maintain cabling standards, design guidelines, naming conventions, labeling requirements, and installation specifications. • Ensure designs comply with applicable TIA, BICSI, IEEE, NEC/NFPA, ISO/IEC, and manufacturer standards . • Support data center capacity planning and determine future fiber, copper, rack, and pathway requirements. • Review contractor installation packages and ensure field implementation aligns with approved designs. • Support fiber testing, copper certification, commissioning, punch-list resolution, and project closeout. • Review OTDR, insertion-loss, and certification test results where applicable. • Participate remotely in design reviews, construction coordination meetings, and technical troubleshooting. • Conduct occasional site surveys and field inspections when required. • Identify design risks, constructability issues, capacity constraints, and opportunities for standardization. • Maintain acc

Apply on employer site ↗