Jobs / United States / Lambda

Lambda

Senior Electrical Delivery Engineer

Remote (USA) · Remote · US only Posted today

View original listing ↗ Tailor my CV first Source: Jobicy

Listed on Jobicy: the application continues on their site, which links to the employer. Optional: we can tailor a CV and cover letter for this job from your real experience first (the first one is free).

Where you can work from

United States only

Based on the listing's location: Remote (USA).

The company's headquarters is not the same as where you may work from. Visa sponsorship only matters if you would relocate; see below.

Visa sponsorship, if you would relocate

Sponsorship verdict

No sponsorship evidence yet

No government record and no wording either way. Not a refusal: ask the recruiter.

  • No government sponsor record hereThis employer posted directly and does not match a government sponsor register.
  • The posting doesn’t mention sponsorshipSilence isn’t a refusal — ask the recruiter before investing much time.
  • No salary bar for this routeH-1B has no fixed salary bar: the employer must pay at least the prevailing wage for the role and area.
  • What Lambda paid sponsored hires in similar roles6 certified filings for “Senior Software Engineer” (Software Developers) in CA: $263k–$296k, median $285k.
  • Confirmed live todayWhen a source last listed this job as open.
Details and sources
No salary bar for this route
H-1B has no fixed salary bar: the employer must pay at least the prevailing wage for the role and area. Cap-subject employers enter a lottery weighted by wage level. Source: https://www.federalregister.gov/documents/2025/12/29/2025-23853/weighted-selection-process-for-registrants-and-petitioners-seeking-to-file-cap-subject-h-1b, rules effective 2026-02-27.
What Lambda paid sponsored hires in similar roles
6 certified filings for “Senior Software Engineer” (Software Developers) in CA: $263k–$296k, median $285k. Most were filed at wage level IV (100%) — 4 lottery entries, ≈61% projected selection odds for cap-subject employers. Source: US Department of Labor LCA disclosure data (Oct 2025 – Jun 2026).

US H-1B: cap-subject employers enter a lottery weighted by wage level — Level I gets 1 entry, Level IV gets 4 (DHS projected selection odds ≈15% at Level I to ≈61% at Level IV). Universities and non-profit research employers are cap-exempt. The $100,000 fee for new petitions from abroad is currently blocked by a court order (appeal pending).

A verdict summarises public evidence. It is not legal advice and never a guarantee: the employer and the immigration authority decide. Sign in to factor in where you can already work.

Before you apply

Sponsorship unknown

No register record and no sponsorship wording in the posting. Worth asking the employer before investing significant time.

These come from the posting’s own wording. Read the original listing to confirm. See better-fit alternatives →

About the role

Lambda , The Superintelligence Cloud, is a leader in AI cloud infrastructure serving tens of thousands of customers. Our customers range from AI researchers to enterprises and hyperscalers. Lambda's mission is to make compute as ubiquitous as electricity and give everyone the power of superintelligence. One person, one GPU. If you'd like to build the world's best AI cloud, join us. What You’ll Do • Perform site walkdowns to verify installed electrical systems against approved designs, single-line diagrams, specifications, submittals, and Lambda standards. • Validate equipment ratings, protection settings, phasing, grounding and bonding, terminations, labeling, redundancy, and electrical failure domains. • Identify installation deficiencies, design conflicts, and operational risks; document punch-list items and drive them through closure. • Review construction test results and witness factory acceptance testing, site acceptance testing, functional testing, and integrated systems testing. • Develop and review energization plans, MOPs, SOPs, EOPs, switching procedures, and electrical safety controls. • Support initial energization and troubleshoot issues involving substations, transformers, switchgear, UPS systems, generators, busway, PDUs, RPPs, and rack-level distribution. • Coordinate with design engineers, engineering partners, utilities, general contractors, electrical trades, equipment manufacturers, commissioning agents, operations, and HPC deployment teams. • Confirm that electrical capacity, voltage, redundancy, monitoring, and protection are ready before IT equipment is energized. • Validate as-built documentation, equipment settings, test reports, commissioning records, and turnover packages before operational handoff. • Capture field lessons and incorporate them into Lambda’s design standards, commissioning requirements, and site-validation playbooks. • Mentor other engineers and provide senior technical leadership during high-risk energization and bring-up activities. You • Have significant experience delivering, commissioning, or operating electrical systems in data centers, mission-critical facilities, utilities, or large industrial environments. • Understand both medium- and low-voltage distribution, including transformers, switchgear, protective relays, generators, UPS systems, busway, grounding, and rack-level power. • Can interpret single-line diagrams, equipment submittals, protection studies, relay settings, test reports, and construction documentation. • Have hands-on experience with site inspections, electrical testing, energization, commissioning, or operational turnover. • Understand electrical safety, lockout/tagout, energized work controls, and applicable NEC, NFPA 70E, IEEE, and NETA requirements. • Can distinguish between cosmetic deficiencies and conditions that create material safety, reliability, or operational risk. • Are comfortable making decisions in the field, escalating critical issues, and coordinating corrective work under schedule pressure. • Communicate clearly with construction teams, engineers, vendors, operators, and senior stakeholders. • Are willing to travel extensively and spend extended periods at active construction and commissioning sites. • Hold a bachelor’s degree in electrical engineering or equivalent practical experience. Nice to Have • Experience commissioning hyperscale, colocation, HPC, or AI data centers. • Experience supporting first energization and initial IT-load or GPU-cluster bring-up. • Familiarity with Level 1–5 commissioning, integrated systems testing, and operational-readiness processes. • Experience with protective-relay testing, breaker testing, insulation-resistance testing, power-quality analysis, or infrared inspections. • Exper

View original listing ↗